1.
J. bras. nefrol ; 46(2): e20230119, Apr.-June 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1550500

RESUMO

Abstract Introduction: Renal osteodystrophy (ROD) refers to a group of bone morphological patterns that derive from distinct pathophysiological mechanisms. Whether the ROD subtypes influence long-term outcomes is unknown. Our objective was to explore the relationship between ROD and clinical outcomes. Methods: This study is a subanalysis of the Brazilian Registry of Bone Biopsies (REBRABO). Samples from individual patients were classified as having osteitis fibrosa (OF), mixed uremic osteodystrophy (MUO), adynamic bone disease (ABD), osteomalacia (OM), normal/minor alterations, and according to turnover/mineralization/volume (TMV) system. Patients were followed for 3.4 yrs. Clinical outcomes were: bone fractures, hospitalization, major adverse cardiovascular events (MACE), and death. Results: We enrolled 275 participants, of which 248 (90%) were on dialysis. At follow-up, 28 bone fractures, 97 hospitalizations, 44 MACE, and 70 deaths were recorded. ROD subtypes were not related to outcomes. Conclusion: The incidence of clinical outcomes did not differ between the types of ROD.


Resumo Introdução: Osteodistrofia renal (OR) refere-se a um grupo de padrões morfológicos ósseos que decorrem de mecanismos fisiopatológicos distintos. É desconhecido se os subtipos de OR influenciam desfechos em longo prazo. Nosso objetivo foi explorar as relações entre OR e desfechos. Métodos: Este estudo é uma subanálise do Registro Brasileiro de Biópsias Ósseas (REBRABO). As amostras de cada paciente foram classificadas em osteíte fibrosa (OF), osteodistrofia urêmica mista (MUO), doença óssea adinâmica (ABD), osteomalácia (OM), alterações normais/menores, e pelo sistema Remodelação / Mineralização / Volume (RMV). Os pacientes foram acompanhados por 3,4 anos. Os eventos clínicos foram: fraturas ósseas, hospitalizações, eventos cardiovasculares adversos maiores (MACE), e óbito. Resultados: Analisamos 275 indivíduos, 248 (90%) deles estavam em diálise. No acompanhamento, 28 fraturas ósseas, 97 hospitalizações, 44 MACE e 70 óbitos foram registrados. Os subtipos de OR não foram relacionados aos desfechos clínicos. Conclusão: A incidência de desfechos clínicos não diferiu entre os tipos de OR.

2.
J. bras. nefrol ; 41(3): 384-392, July-Sept. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1040258

RESUMO

Abstract Introduction: Chronic kidney disease (CKD) has a high prevalence and is a worldwide public health problem. Reuse of dialyzers is a cost reduction strategy used in many countries. There is controversy over its effects on clinical parameters and microbiological safety. Methods: In this clinical crossover study, 10 patients performed consecutive hemodialysis (HD) sessions divided in two phases: "single use" sessions (N = 10 HD sessions) followed by "dialyzer reuse" sessions (N = 30 HD sessions). Clinical, laboratory, and microbiological parameters were collected in the following time points: "single use", 1st, 6th, and 12th sessions with reuse of dialyzers, including bacterial cultures, endotoxins quantification in serum and dialyzer blood chamber, and detection of hemoglobin and protein residues in dialyzers. Results: Mean age of the sample was 37 ± 16 years, 6 (60%) were men, and 5 (50%) were white. CKD and HD vintage were 169 ± 108 and 47 (23-111) months, respectively. Serum C-reactive protein (CRP) [4.9 (2.1) mg/mL], ferritin (454 ± 223 ng/mL), and endotoxin levels [0.76 (0.61-0.91) EU/mL] were high at baseline. Comparison of pre- and post-HD variations of serum levels of CRP and endotoxins in the "single use" versus "reuse" phases did not result in differences (p = 0.8 and 0.4, respectively). Samples of liquid in the dialyzer inner chamber were negative for the growth of bacteria or endotoxins. There was no significant clinical manifestation within and between the phases. Conclusion: Dialyzers reuse was safe from a clinical, microbiological, and inflammatory point of view. The dialyzer performance remained adequate until the 12th reuse.


Resumo Introdução: A doença renal crônica (DRC) é um problema de saúde pública mundial de alta prevalência. O reúso de dialisadores é uma estratégia de redução de custos empregada em muitos países. Seus efeitos sobre parâmetros clínicos e de segurança microbiológica são alvo de controvérsia. Métodos: No presente estudo clínico cruzado, 10 pacientes realizaram sessões consecutivas de hemodiálise (HD) divididas em duas fases: a primeira com sessões de "uso único" (N = 10 sessões de HD) e a segunda com sessões com "reúso de dialisadores" (N = 30 sessões de HD). Parâmetros clínicos, laboratoriais e microbiológicos foram registrados nos seguintes momentos: "uso único", 1a, 6a e 12a sessões com reúso de dialisadores, incluindo culturas bacterianas, quantificação de endotoxinas no soro e na câmara interna do dialisador e detecção de hemoglobina e resíduos de proteína nos dialisadores. Resultados: A idade média da amostra foi de 37 ± 16 anos seis (60%) eram homens e cinco (50%) eram brancos. Os tempos com DRC e em HD foram de 169 ± 108 e 47 (23-111) meses, respectivamente. Os níveis séricos de proteína C-reativa (PCR) [4,9 (2,1) mg/mL], ferritina (454 ± 223 ng/mL) e endotoxinas [0,76 (0,61-0,91) UE/mL] estavam elevados no início do estudo. A diferença dos níveis séricos de PCR e endotoxinas pré e pós-HD nas fases de "uso único" e "reúso" não foi significativa (p = 0,8 e 0,4, respectivamente). As amostras de líquido retiradas da câmara interna do dialisador foram negativas para crescimento de bactérias e endotoxinas. Não houve registro de manifestações clínicas significativas nas fases do estudo. Conclusão: O reúso de dialisadores foi seguro dos pontos de vista clínico, microbiológico e inflamatório. O desempenho do dialisador permaneceu adequado até o 12º reuso.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Diálise Renal/instrumentação , Reutilização de Equipamento , Rins Artificiais/efeitos adversos , Rins Artificiais/microbiologia , Proteína C-Reativa/análise , Projetos Piloto , Seguimentos , Estudos Cross-Over , Endotoxinas/sangue , Insuficiência Renal Crônica/terapia , Ferritinas/sangue , Inflamação/sangue